Table 5.1 (Fenestration)
List of Table 5.1 (Fenestration)
Table 5.1 (Surface)
Table 5.1 (Fenestration)
Table 5.1 A
Table 5.1 B
Lighting
HVAC
Zone
Category
Fenestration ratio
Fenestration
Assembly Max. U-Value
Assembly Max. SHGC
Action
Zone 2
Vertical Glazing
25%-50%
All Assemblies
2.38
0.25
Zone 3
Vertical Glazing
25%-50%
All Assemblies
2.38
0.25
Zone 3
Vertical Glazing
50%-100%
All Assemblies
1.87
0.25
Zone 2
Vertical Glazing
50%-100%
All Assemblies
1.87
0.25
Zone 1
Vertical Glazing
50%-100%
All Assemblies
1.87
0.25
Zone 1
Vertical Glazing
25%-50%
All Assemblies
2.38
0.25
Zone 3
Skylight
0%-3%
Skylight with Curb, Glass
4.259
0.35
Zone 2
Skylight
0%-3%
Skylight with Curb, Glass
4.259
0.35
Zone 1
Skylight
0%-3%
Skylight with Curb, Glass
4.259
0.35
Zone 3
Vertical Glazing
0%-25%
All Assemblies
2.668
0.25
Zone 2
Vertical Glazing
0%-25%
All Assemblies
2.668
0.25
Zone 1
Vertical Glazing
0%-25%
All Assemblies
2.668
0.25
Are you sure