Floor :
Floor1
Floor position
Above-grade
Below-grade
Wall
Window
Door
Skylight
Floor
Roof
Ceiling
Outside boundary condition
Construction assembly
Face 2
Thermal Zone 1
100
0
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
PC_MassWall_BG_U-value
Face 3
Thermal Zone 1
100
0
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
PC_MassWall_BG_U-value
Face 4
Thermal Zone 1
100
0
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
PC_MassWall_BG_U-value
Face 5
Thermal Zone 1
100
0
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
PC_MassWall_BG_U-value
Wall
Fenestration Assembly
Wall
Door Assembly
Outside boundary condition
Construction assembly
Ground
No exterior exposure
Exposed to sun
Ground contact
PC_Massfloor_U-value
PC_Massfloor_G_U-value
Face 0
Floor
Thermal Zone 1
625
0
Outside boundary condition
Construction assembly
Floor :
Floor2
Wall
Window
Door
Skylight
Floor
Roof
Ceiling
Outside boundary condition
Construction assembly
Face 10
Thermal Zone 2
120
4
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
Face 12
Thermal Zone 2
120
4
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
Face 13
Thermal Zone 2
120
4
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
Face 8
Thermal Zone 2
120
4
No exterior exposure
Exposed to sun
Ground contact
PC_MassWall_AG_U-value
Wall
Fenestration Assembly
Face 11
Face 10
sbc 602
53.99999999999994
Face 9
Face 8
sbc 602
53.99999999999997
Wall
Door Assembly
Outside boundary condition
Construction assembly
Surface
No exterior exposure
Exposed to sun
Ground contact
PC_Massfloor_U-value
Face 6
Floor
Thermal Zone 2
625
4
Surface
No exterior exposure
Exposed to sun
Ground contact
PC_Massfloor_U-value
Surface 1
Floor
Thermal Zone 2
275
4
Outside boundary condition
Construction assembly
No exterior exposure
Exposed to sun
Ground contact
PC_Roof_U-value
Face 7
Outdoors
Roof
Thermal Zone 2
900
8
Area details
Wall area
Window area
Floor area
Roof area
WWR
Floor1
400 m
2
0 m
2
625 m
2
0 m
2
0
Floor2
480 m
2
108 m
2
900 m
2
900 m
2
22.5
Total
880 m
2
108 m
2
1525 m
2
900 m
2
22.5