Building EUI Manager
SEEC
Resources
About
FAQ
ARB
ENG
Log Out
Portals
Admin
Projects
Dashboard
Project List
Project menus
Project Details
Designer Details
Envelope
Geometry
Geometry
Envelope Properties
Lighting
Equipment
HVAC
Solar PV/Evaporative System
Generate Label
Simulation Result
Label Report
Projects
Project NB-R-A-654\3-2311 N
Envelope Properties
Envelope Properties
Floor :
Floor1
Floor position
Above-grade
Below-grade
Wall
Window
Door
Skylight
Floor
Roof
Ceiling
Outside boundary condition
Construction assembly
Face 2
Thermal Zone 1
440
0
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 6
Thermal Zone 1
440
0
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 7
Thermal Zone 1
440
0
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 8
Thermal Zone 1
440
0
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Wall
Fenestration Assembly
Face 3
Face 2
Reflective
0.743224320000003
Face 4
Face 2
Reflective
0.7432243199999995
Wall
Door Assembly
Face 5
Face 2
602 Door
1.8589898304
Face 9
Face 8
602 Door
1.8589898303999917
Outside boundary condition
Construction assembly
Ground
No exterior exposure
Exposed to sun
Ground contact
Test_Floor
Face 0
Floor
Thermal Zone 1
3025
0
Outside boundary condition
Construction assembly
Floor :
Floor2
Wall
Window
Door
Skylight
Floor
Roof
Ceiling
Outside boundary condition
Construction assembly
Face 12
Thermal Zone 2
440
8
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 13
Thermal Zone 2
440
8
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 14
Thermal Zone 2
440
8
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 15
Thermal Zone 2
440
8
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Wall
Fenestration Assembly
Wall
Door Assembly
Outside boundary condition
Construction assembly
Surface
No exterior exposure
Exposed to sun
Ground contact
Test_Floor
Face 10
Floor
Thermal Zone 2
3025
8
Outside boundary condition
Construction assembly
Floor :
Floor3
Wall
Window
Door
Skylight
Floor
Roof
Ceiling
Outside boundary condition
Construction assembly
Face 18
Thermal Zone 3
440
16
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 19
Thermal Zone 3
440
16
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 20
Thermal Zone 3
440
16
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Face 21
Thermal Zone 3
440
16
No exterior exposure
Exposed to sun
Ground contact
Double Wall - Concrete Block
Wall
Fenestration Assembly
Wall
Door Assembly
Outside boundary condition
Construction assembly
Surface
No exterior exposure
Exposed to sun
Ground contact
Test_Floor
Face 16
Floor
Thermal Zone 3
3025
16
Outside boundary condition
Construction assembly
No exterior exposure
Exposed to sun
Ground contact
Test_roof
Face 17
Outdoors
Roof
Thermal Zone 3
3025
24
Area details
Wall area
Window area
Floor area
Roof area
WWR
Floor1
1760 m
2
1.48 m
2
3025 m
2
0 m
2
0.08
Floor2
1760 m
2
0 m
2
3025 m
2
0 m
2
0
Floor3
1760 m
2
0 m
2
3025 m
2
3025 m
2
0
Total
5280 m
2
1.48 m
2
9075 m
2
3025 m
2
0.08
Save
Note
:
Please save the data before navigating!
Please save geometry to load the data
Previous
Next
Are you sure
Are you sure you want to delete the data?